Titel

Tandrad, Spindel en Turbine.

Meetbereiken van 0,005 liter/minuut tot 48000 liter/minuut vloeistof
gassen tot 107500 liter/minuut.
Analoge uitgangen, M-bus uitgangen en Frequentieuitgangen.
Nauwkeurigheden tot 0,25% van de meetwaarde.
EExiaIIC uitvoeringen.
Speciale uitvoeringen leverbaar voor o.a.: schurende middelen, verfsoorten,
pharmaceutische vloesitoffen, aromatische vloeistoffen, oliesoorten,
lijmsoorten, wassoorten, etc.

Webmyday-Button-Contact_AEsensors                                                                                                             Webmyday-Button-Offerte_AEsensors

1. Turbine Flow Meter (HM)

Type Eigenschappen Toepassingen Downloads
Turbine Flow Meters (HM) – General Overview
  • Measuring ranges: 0.03…25,000 ltr./min
  • Viscosity range: 0.1…100 mm²/s
  • Linearity: ±0.5% of actual value.
  • Turbine Flow Meters for flow measurement of fuels, light fuel oil, thermal oil, solvents, tap and demineralised water as well as special models for refrigerants, pharmaceutical fluids, cryogenic fluids, liquefied gases and high-pressure applications.
Download
Turbine Flow Meter with Flange Ends
(HM-F)

  • Measuring ranges: 0.03 up to 25,000 l/min
  • Viscosity: 0.1 up to 100 mm²/s
  • LInearity: ±0.5 % of actual value.
  • HM…F turbines are equipped with flanges as per DIN or ANSI.
Download
Turbine Flow Meters with Female Inch Threads
(HM-R)

  • Measuring range: 0.03 bis 400 l/min
  • Viscosity: 0.1 up to 100 mm²/s
  • Linearity: ±0.5 % of actual value.
  • HM…R turbines have inch sized female threads allowing a great variety of connections.
Download
Turbine Flow Meters with Ermeto Fittings (HM-E)
  • Measuring range: 0.3 up to 500 l/min
  • Viscosity: 0.1 bis 100 mm²/s
  • Linearity: ±0.5 % of actual value.
  • HM…E turbines are equipped with Ermeto fittings.
Download
Turbine Flow Meters for Pharmaceutical Applications (HM-TRI)
  • Measuring range: 0.3 up to 400 l/min
  • Viscosity: 0.1 up to 100 mm²/s
  • Linearity: ±2.0 % of actual value.
  • For sanitary and purity reasons HM…TRI turbines have the following features:
    Threadless tube fittings type „Tri-Clamp“ as per DIN 32676
    Special construction eleminating dead spots
    Slide bearing with lateral bores to enable flush processes.
Download
Aluminium Turbine Flow Meters (HM-U)
  • Measuring ranges: 1.2 up to 600 l/min
  • Viscosity: 0.1 up to 100 mm²/s
  • Linearity: ±1.5 % of actual value
  • Pressure: max. 400 bar.
  • Aluminium Turbine Flow Meters with ball bearings for hydraulic applications.
Download
Turbine Flow Meters for Subsea Applications
(HM-Subsea)
  • Measuring range: 0.3 up to 500 l/min
  • Viscosity: 0.8 up to 100 mm²/s
  • Linearity: ±1 % of actual value.
  • Pressuer: up to 1400 Bar.
  • Materials:
    • Housing: as per 1.4404 (AISI 316L), others on request
    • Wheels: as per DIN 1.4460 (AISI 329), others on request
    • Bearing: tungsten carbide
  • HM turbine flowmeters for underwater applications are reliable, durable and robust flow instruments, specially developed for challenging submarine flow applications.
Download

2. Helical Flow Meter (SRZ)

Type Eigenschappen Toepassingen Downloads
Helical Flow Meters in Standard Design
(SRZ-ST)

  • Measuring range: 0.4…400 l/min
    Viscosity: max. 1×10^6 mm²/s
    Linearity: ±0,25 % of actual value
    Pressure: max. 400 bar.
  • Flow meters for epoxy resigns, PVC and underbody sealants, anti-flutter materials, adhesives, polyurethane, polymers, sealants, petrochemicals and thixotropical fluids, grease, oil, glues, heavy fuel oil.
Download
Helical Flow Meter with Integral Double Pickup (SRZ-Compact)
  • Measuring range: 0.4….400 l/min
  • Viscosity: max. 1×10^6 mm²/s
  • Linearity: ±0,25 % of actual value
  • Pressure: max. 400 bar.
  • Compact flow meter with integral double pickup for flow measuerement of epoxy resigns, PVC and underbody sealants, anti-flutter materials, adhesives, polyurethane, polymers, sealants, petrochemicals and thixotropical fluids, grease, oil, glues, heavy fuel oil.
Download
Helical Flow Meters with Ball Bearings (SRZ-KL)
  • Measuring ranges: 0.4…400 ltr./min
  • Viscosity: max. 1×10^6 mm²/s
  • Linearity: ±0.25% of actual value
  • Pressure: max. 400 bar.
  • The series SRZ KL flowmeter (KL for ball bearing version) is a volume flow meter intended primarily for lubricating, non-abrasive fluid applications.
Download
Helical Flow Meter High Resolution
(SRZ-HR)

  • Measuring range: 0.4….40 l/min
  • Viscosity: max. 1×10^6 mm²/s
  • Linearity: ±0,25 % of actual value
  • Pressure: max. 400 bar.
  • The High Resolution helical flow meter series is used mainly in applications with highly viscous, abrasive and filled, lubricating and non-lubricating media. Extremely high-resolution electronics integrated in the measuring equipment support the measurement of the smallest dosage quantities in applications with the highest reproducibility requirements.
Download

3. Gear Flow Meter (ZHM)

Type Eigenschappen Toepassingen Downloads
Gear Flow Meter Std (ZHM-ST)
  • Standard version
    Stainless steel meters
    lubricating and nonlub-ricating fluids
  • Measuring range: 0.005…1000 l/min,
    pressures up to 630 Bar.
  • Gear flow meters are positive displacement meters which are used in various applications. KEM offers a great variety of models e.g. for paints, underbody seal, sealants.
Download
Gear Flow Meter with Ball Bearings
(ZHM-KL)
  • Measuring range: 0.002…1000 l/min
    Auccuracy: up to ±0,1%
    Linearity: ±0.5 % of actual value,
    Pressure: max. 630 bar.
  • Gear Flow Meter with ball bearings.
Download
Gear Flow Meters FlowPod Series
(ZHM-CI)
  • Measuring range: 0.002… up to 70 l/min
    Repeatability: ±0.1 % of actual value
    Linearity: ±0.5 % of actual value
    Pressure: max. 1035 Bar
    Temperature: -/-20°C…+75°C.
  • Gear flow meter ZHM-CI Series is a dedicated version, which is primarily used in applications for the upstream oil and gas market.
Download
Gear Flow Meter Cartridge Design
(ZHM-CT)

  • Cartridge design
    Stainless steel or Aluminium
    For quick media changes.
  • Measuring range: 0.005…3 l/min,
    pressures max 315 Bar.
  • Stainless steel meter with optimized space for quick media changes and short wash cycles. Patented “light-weight design“.Aluminium version: Cost-effective flowmeter for lubricating fluidsand.
Download
Aluminium Gear Flow Meters (ZHA-KL)
  • Measuring ranges: 0.02…1000 l/min
    Viscosity range: 5…25,000 mm²/s
    Linearity: ±0.5% of actual value,
    Pressure: max. 315 bar.
  • Aluminium Gear Flow Meters with ball bearings.
Download
Gear Flow Meters for High Pressure Applications
(ZHM-HP)
  • Measuring range: 0.002… up to 70 l/min
    Repeatability: ±0.1 % of actual value
    Linearity: ±0.5 % of actual value
    Pressure: max. 1035 Bar
    Temperature: max.
    +150 °C.
  • Gear Flow Meters for High Pressure Applications with Autoclave Connections up to 1035 Bar.
Download
Gear Flow Meters for Low Viscous, Lubricating Fluids
(ZHM- MK)

  • Measuring range: 0.002… up to 70 l/min
    Repeatability: ±0.05 % (under the sam conditions)
    Linearity: ±0.1 % of actual value
    Pressure: max. 345 Bar
    Temperature: max.
    +180 °C.
  • The ZHM MK gear flow meter are flow meters which are mainly used in lubrication and non-viscous liquids. Therefore they are used especially for the fuel consumption measurement and the dosing of low viscous media.
Download
Gear Flow Meters for High Resolution Serie
(GFM)
  • Measuring range: 0.002… up to 25 l/min
    Repeatability: ±0.05 % (under the same conditions)
    Linearity: ±0.5 % of actual value
    Pressure: max. 250 Bar
    Temperature: max.
    +150 °C.
  • Gear Flow Meters for High Pressure Applications with Autoclave Connections up to 1035 Bar.
Download

 

Webmyday-Button-Contact_AEsensors                                                                                                               Webmyday-Button-Offerte_AEsensors

4. Micro Flow Meter (LFM)

Type Eigenschappen Toepassingen Downloads
Micro Flow Meter
for low-viscosity fluids in dosing and filling systems
(LFM)
  • Measuring range: 0.005…0.25 l/min
  • Viscosity: 0.6…6 mm²/s
  • Linearity: ±2.5 % of actual value.
  • The LFM micro-flowmeter is suitable for low-viscosity fluids in dosing and filling applications of all kinds.
Download

5a. Puls Pick-up Versterkers

Type Eigenschappen Toepassingen Downloads
Carrier-Frequency Pulse Amplifiers (VTE*/P Ex)
  • Supply voltage: UB: +8.5 up to 29 VDC, controlled
  • Quiescent current: IR < 5 mA
  • Frequency range: 2 up to 4,000 Hz according to flow meter.
  • Carrier-frequency pulse amplifiers for all KEM flow meters fits most applications.
Download
Carrier-Frequency Pulse Amplifiers for direct mount (VTE*Ex)
  • Supply voltage: UB: +10 up to 30
  • Quiescent current: IR < 2 mA
  • Frequency range: 0,5 up to 5,000 Hz according to flow meter.
  • Frequency pulse amplifiers for all KEM flow meters, for direct mount (LFM and ZHM) or screw in mount.
Download
Carrier-Frequency Pulse Amplifiers (VTE*Ex)
AEsensors_Tandrad_22_PulseAmplifiers(VTE-Ex)
  • Supply voltage: UB: +8 up to 29 VDC
  • Quiescent current: IR < 4 mA
  • Frequency range: 3 up to 3,000 Hz according to flow meter.
  • Carrier-frequency pulse amplifiers for all KEM flow meters.
Download
Carrier-Frequency Pulse Amplifiers for ZHM…CT and LFM (VTE-C*Ex)
AEsensors_Tandrad_23_CTandLFM
  • Supply voltage: UB: +9 up to 29 VDC
  • Quiescent current: IR < 4 mA
  • Frequency range: 1.5 up to 3,000 Hz according to flow meter.
  • Carrier-frequency pulse amplifiers for gear flow meter in cartridge design and micro flow meter.
Download
Carrier-Frequency Pulse Amplifier with Dual Pickup (TD-Ex)
AEsensors_Tandrad_24_ DualPickup(TD-Ex)
  • Supply voltage: 8 up to 30 VDC
  • Quiescent current: < 4 mA each channel
  • Frequency range:3 up to 3,000 Hz in accordance with flow meter.
  • Carrier-frequency pulse amplifier with dual pickup for pulse doubling and reverse-flow detection.Suitable for ZHM series.
Download
Inductive Pickups and Amplifiers for Extreme Fluid Temperatures (IF and VIE)
AEsensors_Tandrad_25_FluidTemperatures(IFandVIE)
  • Max +150°C for SRZ Helical flow meters
  • Max +180°C for ZHM Gear flow meters
  • Max +350°C for HM Turbine flow meters.
  • Inductive pickups and amplifiers for extreme fluid temperatures from –273 up to +350°C.
Download
Fibreoptical Amplifier and Lightpulse Receiver (FOP and OPTV)
AEsensors_Tandrad_26_LightpulseReceiver(FOPandOPTV)
  • Power supply: lithium battery
  • Ambient temperature: –20 up to +50°C
  • Ex protection:
  • ATEX: EX II 2 G EEx ia IIC T4/T5/T6
  • CSA: Ex ia IIC; Class I, Zone 0, AEx ia IIC.
  • Fibreoptical amplifier and lightpulse receiver for applications in electrostatical painting systems.
Download
Halleffect Pulse Amplifiers for Aluminium Gear Flow Meters (VHE* and VHD*)
AEsensors_Tandrad_27_FlowMeters(VHEandVHD)
  • Supply voltage: 12 up to 24 VDC, max. 10 mA
  • Frequency range: 1 up to 3,000 Hz
  • Output: squarewave pulses.
  • Halleffect Pulse Amplifier sfor aluminium gear flow meters. Also available with dual pickup for pulse doubling and reverse-flow detection.
Download

Type Eigenschappen Toepassingen Downloads

5b. Analoge Pick-up Versterkers

Local Converters with Interface (WT.02/WI.02)
  • Output signal: 4-20 mA, 2-wire (passive)
  • Operating voltage: 12-30 V, regulated
  • Measuring frequencies: 1 up to 3,000 Hz according to flow meter
  • Allowable load: 20 mA, max. 800 Ohm (Voltage dependent).
  • The converters are passive 4-20 mA sensors with carrier-frequency-input stage (WT.02) or inductive input stage (WI.02). Both analogue and frequency output can be linearized with up to 10 points.The carrier frequency converters WT.02 are recommended for low flow due to the low lower cut off frequency (typ. < 0.5 Hz).The inductive converters WI.02 are recommended for higher medium temperatures (up to +150°C).
Download
Local Display with Current and Frequency Output (VTC/VIC)
AEsensors_Tandrad_30_FrequencyOutput(VTC-VIC)
  • Carrier frequency or inductive pickup
  • Analog output 4 – 20 mA passive (2 wire)
  • Frequency output, freely scalable, Push Pull or NAMUR
  • 20 point linearization of the measured value, 3 banks
  • Control input
  • KEM interface (standard) or USB or HART
  • Ex-Approval: ATEX Ex II 2G Ex ia IIC T4 Gb.
  • The VTC / VIC are high precision 4 – 20 mA pickups with a display and a frequency output.
Download
Local Display for Wall Mount with integrated Frequency- and Analog Output (VTG/VIG)
AEsensors_Tandrad_31_AnalogOutput(VTG-VIG)
  • Carrier frequency or inductive pickup
  • Analog output 4 – 20 mA passive (2 wire)
  • Frequency output, freely scalable, Push Pull or NAMUR
  • 20 point linearization of the measured value, 3 banks
  • Control input
  • KEM interface (standard) or USB or HART
  • Ex-Approval: ATEX Ex II 2G Ex ia IIC T4 Gb.
  • The VTG/VIG are high precision 4 – 20 mA pickups with a display and a frequency output.
Download
Local Display Unit battery-powered (VTB)
AEsensors_Tandrad_32_battery-powered(VTB)
  • LCD-display: 7 digits (7 segments), digit height 12 mm for real time value, totals and parameterization
  • Ambient temperature: –40 up to +50°C
  • Fluid temperature: –40 up to +120°C
  • Ex-protection: EX II 2G Exd (ia) II T4.
  • The VTB is a programmable local display unit with integral carrier frequency pickup and amplifier.
Download
Panel Mount Display with Current and Frequency Output (FAS100)
AEsensors_Tandrad_33_FrequencyOutput(FAS100)
  • Frequency input for 24V digital signals
  • Analogue output 4 – 20 mA
    24V frequency output, freely scalable
  • 20 point linearization of the measured value
  • Control input and output
  • RS485 interface.
  • The FAS100 are high precision frequency meter for panel mount, with control outputs.
Download
Wall Mount Display with Current and Frequency Output (FAW100)
AEsensors_Tandrad_34_FrequencyOutput(FAW100)
  • Frequency input for 24V digital signals
  • Analogue output 4 – 20 mA
    24V frequency output, freely scalable
  • 20 point linearization of the measured value
  • Control input and output
  • RS485 interface
  • Power supply: 24V DC or 100 to 240V AC.
  • The FAW100 are high precision frequency meter for panel mount, with control outputs.
Download
Frequency to Analogue Converter (FAU 50 und FAU 60)
AEsensors_Tandrad_35_Converter(FAU50undFAU60)
  • Analogue output: 0/2 up to 10V or 0/4 up to 20mA
  • Resolution: 13 bit
  • Impedance current output: < 1,000 Ohm
  • Impedance voltage output: > 3,000 Ohm
  • Divider pulse output: galvanically free, open collector: 30V, 50mA
  • Pulsetime: 0.2 up to 100 ms, programmable.
  • The FAU is a microprocessor-based unit to convert the output frequencies of KEM flow meters in a range from 3 up to 5,000 Hz into a potential-free analogue signal with a resolution of 13 bit.
Download
Intrinsically Safe Power Supply Unit (EWS)
AEsensors_Tandrad_36_SupplyUnit(EWS)
  • Outputs
    Open collector
    PLC output active 24 V
    NAMUR DIN 19234.
  • Intrinsically safe supply circuit 12 V to supply intrinsically safe KEM pickups and amplifiers installed in hazardous areas.
Download

Webmyday-Button-Contact_AEsensors                                                                                          Webmyday-Button-Offerte_AEsensors